PERFECT LOCKING FOR EACH DOOR

ELECTRONIC LOCKING SYSTEMS
ELECTROMECHANICAL LOCKS
 


 

 

 

 



Used to electronic lock of electric strikes, electromagnetic locks, access control and control of the working time. Can be used to lock lifts, cupboards and more. May turn on or off electric consumers through integrated relay. Works with contact keys type iButton. The reader and the keys are extremely wear resistant - at least 10 years, resistant to vandalism, are easy to use and with a high degree of secrecy. There is an intelligent antiskaning system, protection from electromagnetic effects back-up memory, opportunity to work with emergency power. There is an inlet to monitor the state of the door and inlet for monitoring of alarm conditions. Extremely high flexibility, programmable features, reliability and security. Opportunity for computer connection. Record of events takes place in chronological order or the exact date and time, depending on the model of lock.

Set of electronic lock Bulkey includes: plant, a reader and master key.

Model electronic lock

ÂKU 110

ÂKU 210

ÂKU 310

ÂKU 410

Maximum number of keys

128

999

128

999

Maximum number of events

96

4064

96

4064

Real-time clock

No

No

Yes

Yes

Price in BGL

90

100

105

120

Using the multifunctional electronic lock Bulkey for elevator control shall be decided the majority of users’ problems. Locking for unauthorized access and using the elevator, there are several options:

Variant I: Fully disconnection the calls of the elevator from the floors and the choice of floor from the cabin through an electronic plant Bulkey - there are two types of operation and installation:

Type 1: The principle of control is the following: Readers are installed on the floors and in the cab. To call the elevator, it is necessary to touch the key to the reader, and then press the button to call. Going into the elevator cab is the same – first touch the key to the reader and then select the desired floor.

The principle of installation is as follows: On each floor is installed a reader. They stick together and connect through the parallel twisted cable (UTP cable for computer network) on one of the entrances of the plant. On the second entrance of the plant is connected the reader that is mounted in the cab – a cable starts from the reader, which together with the cables of the elevator cab go to the central management of the elevator. There is mounted electronic plant Bulkey, which interrupts the operation of buttons in the cab and for calling from the floors by its relay.

Disadvantage of this kind of Variant I is downloading and the availability of cable between the cab and central management, which moves and bends with the other wires and may cause problems over time. To avoid this, you can use this second kind of this variant or Variant II.

Type 2: The principle of control is as follows: Readers are installed on the floors. To call the elevator, it is necessary to touch the key to the reader. After the elevator cab came the key must be touched again to the reader and then enter into the cab and choose the button for desired floor.

The principle of installation is as follows: On each floor is installed a reader. They stick together and connect through the parallel twisted cable (UTP cable for computer network) on one of the entrances of the plant. In the elevator cab does not install a reader. Plant is installed in the cabinet for the central management of the lift, where through its relay interrupts the work of the buttons for selecting the floor in the cab and call on the floors.

This type of lift off is the cheapest and solves all problems for the whole of its control. The disadvantage is that it is necessary to touch the electronic key twice to the reader mounted on the outside on the floor - once to call the elevator and the second time to choose a floor, since there is no reader in the cab for control.

Variant II: Complete disconnection the calls of the lift from floors and the choice of floor in the cabin through two electronic plants Bulkey

The principle of control is the following: Readers are installed on the floors and in the cab. To call the elevator, it is necessary to touch the key to the reader, and then press the button to call. Going into the elevator cab is the same – first touch the key to the reader and then select the desired floor.

The principle of installation is as follows: On each floor is installed a reader. They stick together and connect through the parallel twisted cable (UTP cable for computer network) on one of the entrances of the plant. Plant is installed in the cabinet for the central management of the lift, where through its relay interrupts the work of the buttons for calling from floors. The second plant is installed on the elevator cab and into the cab is installed its reader.

Variant III: Disable buttons for selecting the floor in the elevator cabin, through a electronic plant Bulkey

The principle of control is as follows: Readers are installed on the floors and in the cab. To call the elevator, it is necessary to touch the key to the reader, and then press the button to call. Going into the elevator cab is the same – first touch the key to the reader and then select the desired floor.

The principle of installation is as follows: The plant is installed on the elevator cab, and inside the cabin of the panel is installed its reader. Disadvantage of this variant is that the buttons on the floors work and small tricks, as load of the elevator for use by unauthorized persons as well as its call by button for the desired floor of it remain.


Electronic keys type IButton are very ergonomic, comfortable and reliable with very long service life and high level of security. Electronic key has a 64 bit code, meaning that there are 18,000,000,000,000,000,000 combinations. Through specially designed antiskaning and in the presence of so many combinations of the code, the system provides extremely high reliability protected by unlocking using high-tech computers and systems. With consumer electronic keys can lock and unlock and incorporate certain features. These keys can not manage the system. They can be deleted, temporarily prohibited or authorized to work in the system. If a key has been deleted or banned from the memory of the system, it can not operate with it. All transactions related to recording a new key, delete key, a temporary ban on key, control system are carried out by the owner through the master key. Master key is primary, the only key for the system, through which it manages. It can not be deleted. With one key you can unlock the entrance door, elevator, garage, cellar, your home. For example, it can be done so some keys can open the entrance door and the elevator and some other – only the entrance door and this is defined by the owner of the master key of the system.

Number of keys

Price /BGL/

from 1 tî 4

15

over 5

12

over 10

10

over 50

8

The price of electronic keys type iButton is determined by the quantity purchased at once.







In addition to the multifunctional electronic lock, you can rely on a data cable with specialized software with which to make control and management of the system BulKey extremely easier:
- Quick and easy key management - delete, entry of new keys, a temporary ban on keys;
- Setting the built-in clock of the locking system;
- Setting up the programmable functions of the locking system;
- Review and adjustment of system parameters;
- Reading and viewing of system errors;
- Reading of the statistics of locking systems;
- Maintenance of database users;
- Download and store files from a locking system with information which, when and what happened to the locking system;
- Filters for Quick Search events by user criteria;
- Ability to complete and detailed records of archive;
- Export filters;
- Many other options.

Price: 100 lv.



 

 

 